

The enhanced filtering options enable objects in the drawing to be filtered based on, for example, duct or pipe series. The tool also introduces a tree view for selecting which property values to change. The upgraded Change Properties tool enables you to change multiple properties simultaneously, filter objects more efficiently and select properties faster using free text search. The length value can be either calculated automatically based on the wire lengths in the drawing or defined manually by the user. The longest branch length is stored in circuit information. The longest branch length can be calculated also in communication, data and building automation circuits. The data can be updated using the Update Drawing Data function. Each circuit contains the data on the number of devices belonging to the circuit, enabling the user to easily check that the circuit does not include too many devices. It is now possible to calculate the number of devices and the longest branch length in low-voltage (LV) and extra-low voltage (ELV) circuits. Calculate number of devices and the longest branch in LV and ELV circuits With this new option, the user can index for example all devices along a fire alarm loop with a couple of mouse clicks.ģ. All you need to do is select the first and the last devices to be indexed along the circuit, and the function will automatically index all devices between the selected start and end points based on the rules defined in the validity settings. The new time-saving Running Index option, Between, enables all objects from a user-selected part of the circuit to be indexed. Validity can be set based on power and communication devices, and even cables. If the defined value range is exceeded, MagiCAD will notify the user to change the defined Running Index format. For example, if you define a value range of “1 to 24” and set “data sockets” as the validity condition, the numbers from 1 to 24 can only be used for indexing data sockets. The enhanced Running Index tool allows the user to define a value range and validity settings, enabling only the valid devices to be indexed from a group of selected devices.

Define a value range and validity settings for Running Index MagiCAD 2019 is compatible with the new AutoCAD 2019, as well as with the previous four AutoCAD versions 2015-2018, including verticals AutoCAD MEP and AutoCAD Architecture.Ģ. Please see also the feature highlights from the latest MagiCAD 2018 UR-1, UR-2 and UR-3 releases. MagiCAD 2019 includes all of the new features and improvements from previous MagiCAD releases. Click here to see MagiCAD 2019 for Revit features »
